Access to information is restricted depending on your login.
Request login-information through our contact form.
Connect a 5-Wire Touch Panel to the Trizeps 4-wire Touch Controller
Driver with 4-wire and 5-wire functionality for WINCE 6.0 Trizeps-IV Series: ucb_touch.zip
Set Registry Keys to set 5-Wire Mode:
[HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\TOUCH]
"CalibrationPoints"=dword:5 ; 5 or 13 (0d) pts (5=default)
"FiveWire"=dword:1 ; Fivewire: TSMX=Input TSPX=TL, TSPY=TR, GND=BL, TSMY=BR,
"PressureL"=dword:0c ; default value for 5-wire.
"PressureH"=dword:1F ; default value for 5-wire.
;!!! Note pressure measurement result is much lower than in 4-wire mode !!!
;!!! Be sure that codec offset values do not conflict with your settings!!!
If 5 Calibrationpoints are selected: The Calibration Points are (in display-resolution percent x, percent y )
For lower than VGA: 1) 50,50, 2) 10,10, 3) 10,90, 4) 90,90, 5) 90,10 VGA or higher : 1) 50,50, 2) 20,20, 3) 20,80, 4) 80,80, 5) 80,20
If 13 Calibration Points are selected: The Calibration Points are (in display-resolution percent x, percent y )
All Displays : 1) 50,50, 2) 25,25, 3) 25,75, 4) 75,75, 5) 75,25,
6) 05,05, 7) 05,50, 8) 05,95, 9) 50,95, 10) 95,95,
11) 95,50, 12) 95,05, 13) 50,05
To use this driver:
1) add the new registry keys to your platform.reg
2) copy it to your BSP binary folder: %_PLATFORMROOT%\%_TGTPLAT%\binary\target\ARMV4I\retail (and ,,,\debug)
3) copy it to %_FLATRELEASEDIR% or build current BSP
4) and rebuild your image.
To get the environment path-variables you can open a command window from VS2005 with ' 'Build/Open Releasedirectory in Build Window' ' and get the variable values by entering ' 'set _FLATRELEASEDIR' ' for instance.
See Also
(C) 2009 Keith & Koep GmbH. All rights reserved. Terms of Use